Measuring accuracyDeviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
-1/0 bar < ± 1 % FSO
< ± 0.5 % FSO
Measuring rangeSee ordering table
Overpressure safetyAt least 2 x FS
250 bar:400 bar
400 bar:650 bar
Burst pressure
< 400 bar:At least 3 x FS
400 bar:1000 bar
Operating temperature range
Medium:-25/+125 °C
Ambient:-25/+85 °C
Storage:-40/+85 °C
Temperature error band≤ ± 0.3 % FSO/10 K In compensated range -25/+85 °C
Dynamic characteristics
Response time:≤ 10 ms
Process connectionG½B EN 837-1/7.3
G½B DIN 3852 type E with protruding diaphragm
Material
Housing:Stainless steel 304
Pressure connection:Stainless steel 304
Diaphragm:Ceramic (Al2O3 96 %)
Seal:FKM (Viton)
Supply voltageDC 8 – 32 V
Output signal2-wire, 4–20 mA
LoadRMax = [(UB – UBMin)/0.02 A] Ω
Current input< 25 mA
Electrical protectionShort circuit proof and protected against reverse polarity
Degree of protectionIP65 (EN 60529)
CE conformityEMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU