Nominal size100
Accuracy class (EN 837-1/6)1,0
Measuring accuracyDeviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
< ± 0.5 % FSO
≤ ± 0.2 % FSO/Jahr
Measuring rangeSee ordering table
Application area
Static load:Full scale value
Dynamic load:0.9 x full scale value
Short-term load:1.3 x full scale value
Operating temperature range
Medium:-20/+100 °C
Ambient:-20/+60 °C
Storage:-40/+70 °C
Temperature error band≤ ± 1 % FSO/10 K In compensated range 0/70 °C
HousingS3
WindowLaminated safety glass
Process connectionG½B EN 837-1/7.3, bottom
Material
Housing:Stainless steel 304
Pressure connection:Stainless steel 316 L
Diaphragm:Stainless steel 316 L
Seal:FKM (Viton)
Pressure transmission liquidSilicone oil
Supply voltageDC 12 – 36 V
Output signal2-wire, 4–20 mA
LoadRMax = [(UB – UBMin)/0.02 A] Ω
Current input< 25 mA
Electrical connectionJunction box
Degree of protectionIP54 (EN 60529)