FunctionsUnits switching,
Min./max. value memory,
Zero and full scale calibration,
Adjustable auto-off function,
Adjustable decimal point,
Battery status indication
Indication of measured valuesbar, mbar, psi, inHg, mmHg, cmHg, kPa, MPa oder mWS
Selectable pressure unit
DisplayMulti-line LCD,
4.5 digit, numeric, for displaying the measured value (character height 9.5 mm) – line 1,
6-digit, alphanumeric, for displaying additional information (character height 6.8 mm) and additional symbols – line 2,
Display can be rotated by 330°
Measuring accuracyDeviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
± 0.5 % FSO (BFSL)
Measuring rangeSee ordering table
Overpressure safetyAt least 1.5 x FS
Burst pressure≤ 160 bar at least 2.5 x FS
> 160 bar at least 1.5 x FS
Operating temperature range
Medium:-20/+125 °C
Ambient:-20/+45 °C
Storage:-30/+80 °C
Temperature error band≤ ± 0.5 % FSO/10 K In compensated range 0/70 °C
Dynamic characteristics
Measuring rate:5 Hz
Process connectionG¼B (EN 837-1/7.3)
Material
Housing:PA6, glass-loaded
Process connection:Stainless steel 304
Diaphragm:Ceramic (Al2O3 96 %)
Seal:FKM
Degree of protectionIP51 (EN 60529)
Supply voltage1 x 3.6 V lithium battery
Service life up to 5 years, depending on use
CE conformityEMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU module A