Measuring accuracyDeviation from the characteristic curve according to IEC 60770 – limit point calibration (non-linearity, hysteresis, repeatability)
< ± 0.5 % FSO
Measuring rangeSee ordering table
Overpressure safety
≤ 250 bar:At least 2 x FS
> 250 bar:At least 1.5 x FS
≥ 1,000 bar:At least 1.2 x FS
Burst pressure
≤ 250 bar:At least 3 x FS
> 250 bar:At least 2 x FS
≥ 1,000 bar:At least 1.5 x FS
Operating temperature range
Medium:-40/+125 °C
Ambient:-40/+105 °C
Storage:-40/+125 °C
Temperature error band≤ ± 0.15 % FSO/10 K In compensated range -25/+85 °C
Dynamic characteristics
Response time:< 1 ms
Process connectionG½B EN 837-1/7.3
Material
Housing:Stainless steel 304
Pressure connection:Stainless steel 630
Supply voltageDC 10 – 32 V
Output signal2-wire, 4–20 mA
LoadRMax = [(UB – UBMin)/0.02 A] Ω
Current input< 25 mA
Electrical protectionShort circuit proof and protected against reverse polarity
Electrical connectionConnector and junction box as per ISO 4400 (DIN 43650-A)
Degree of protectionIP65 (EN 60529)
CE conformityEMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Pressure Equipment Directive 2014/68/EU